2GIG GoControl 1

Introduction

Note

The following is specifically for the 2Gig GoContol (aka the “GoControl One”), but may prove useful for the Vivint SkyPanel and the GoContol 3.

Features

Programming Guide

Q1. Wireless Zones

Sensor Type

1 Entry/Exit 1 Main doors. Gives an entry delay.
2 Entry/Exit 2 Secondary doors. Gives an entry delay, possibly different from Type 1. I often use these for garage overhead and basement doors.
3 Perimeter Windows and “window-like” (e.g. Glass breaks, doors that aren’t typically used for entry and exit). Unlike Types 1 & 2, these sensors, when opened, set off the alarm without delay.
4 Interior Follower Motion detectors, although I usually use Type 10 instead.
5 Trouble Day/Alarm Night I’ve never actually used this...
6 24 Hour Silent Similiar to the Duress Code.
7 24 Hour Audible Similiar to the Police “panic” button.
8 24 hour Auxiliary Flood and Freeze detectors. Has a series of sub-types to cover medical issues, general panics, freeze (low temperatue), water, etc; be sure to select the right one.
9 Fire Smoke Detectors. Doesn’t require verification.
10 Interior with Delay Motion Detectors. When set off, gives you a delay before setting off the alarm, similiar to Type 1.
14 Carbon Monoxide
16 Fire (with Verification) “Firefighters”. Used for a sensor that doesn’t have the fire detection on-board, but relies to something else to detect the fire.
23 No Response Information-only sensors. Won’t set off the alarm. Also useful as a temporary measure if a sensor is mis- behaving.
24 Silent Burglary I’ve never used this.
25 Repeater For signal repeaters. Not available on GoControl; use Type 8 – Contact instead.

Equipement Codes

If the peice of equipment you’re installing insn’t listed, select 0000, and then on the next option enter the approriate 4 digit code.

Note

This list is incomplete.

0000 Other
0862 2GIG-DW10-345 Thin D/W (Surface) Contact
0863 2GIG-DW20-345 Recessed Door Contact
0869 2GIG-PIR-345 Motion With Pet Immunity
0864 2GIG-GB1-345 Glass Break Detector
0872 2GIG-SMKE1-345 Smoke Detector (USA)
0871 2GIG-SMK1-345C Smoke Detector (Canada)
1058 2GIG-SMKT3 Smoke Detector
0868 2GIG-PANIC1-345 Panic Button Remote
0860 2GIG-CO1-345 CO Detector (USA)
0859 2GIG-CO1-345C CO Detector (Canada)
1026 2GIG-CO3 CO Detector
0873 2GIG-TAKE-345 Takeover Module
0866 2GIG-KEY1-345 Keyfob
0867 2GIG-PAD1-345 Keypad
1283 2GIG-TILT1 Tilt Sensor (use loop 1)
0941 RE224GT / RE224DT Resolution Wireless Repeater (GE / DSC)
1061 RE206 Tilt Sensor
1248 Vivint GB2 Glass Break Detector
1249 Vivint PIR2 Motion Detector
1250 Vivint SKEY2 Keyfob
1251 Vivint DW11 Thin D/W (Surface) Contact
1252 Vivint DW21R Recessed Door Contact
1253 Vivint Panic2 Panic Pendant
0637 Honeywell D/W “5816”
0470 Honeywell R-D/W “5818MNL”
0533 Honeywell PIR “5890”
0530 Honeywell PIR “5894PI”
0519 Honeywell Glass Break “5853”
0589 Honeywell Smoke “5008W3”
0557 Honeywell Heat Sensor “5809”
0624 Honeywell Flood Sensor “5821”
0491 Honeywell Panic Pendant “5802MN2”
0616 Existing Smoke Detector

Voice Descirptions

Note

This list is incomplete.

002 abort
003 ac
004 access
005 alarm
006 and
007 announcement
008 area
009 arm
010 armed
011 arming
012 at
013 attic
014 audio
015 auto
016 automation
017 auxiliary
018 away
019 babys
020 back
021 basement
022 bathroom
023 battery
024 bedroom
025 bonus
026 break
027 button
028 bypass
029 bypassed
030 cabinet
031 cancel
032 carbon monoxide
033 cellar
034 cellular
035 cell radio
036 center
037 check
038 chest
039 childrens
040 chime
041 closet
042 code
043 communications
044 computer
045 control
046 cool
047 crawl
048 current
049 day
050 degrees
051 den
052 detector
053 dim
054 dining
055 disarm
056 disarmed
057 dock
058 door
059 downstairs
060 driveway
061 east
062 eight
063 eighteen
064 eighty
065 electric
066 eleven
067 emergency
068 enter
069 entrance
070 entry
071 error
072 exercise
073 exit
074 exit now
075 exterior
076 external
077 failure
078 family
079 fan
080 fifteen
081 fifty
082 fire
083 fire alert
084 fire detector
085 first
086 five
087 flood
088 floor
089 fluid
090 foil
091 for
092 forty
093 four
094 fourteen
095 fourth
096 freeze
097 freezer
098 front
099 furnace
100 game
101 garage
102 gas
103 glass
104 glassbreak
105 guest
106 gun
107 hall
108 hallway
109 hanging
110 hang up
111 heat
112 high
113 home
114 house
115 ice
116 inside
117 instant
118 interior
119 intrusion
120 is
121 key
122 keyfob
123 keypad
124 kids
125 kitchen
126 laundry
127 left
128 level
129 library
130 light
131 lights
132 liquor
133 living
134 loading
135 lock
136 loft
137 low
138 main
139 maintenance
140 master
141 medical
142 medicine
143 menu
144 middle
145 monitor
146 motion
147 motion detector
148 mud
149 nine
150 nineteen
151 ninety
152 north
153 not
154 not ready
155 no delay
156 no entry delay
157 nursery
158 off
159 o#ce
160 on
161 one
162 one hundred
163 output
164 outside
165 panel
166 panic
167 pantry
168 patio
169 perimeter
170 phone line
171 play
172 police
173 pool
174 pound
175 power
176 press
177 previous
178 pump
179 radio
180 ready
181 rear
182 relay
183 remote
184 repeat
185 rf jam
186 right
187 room
188 safe
189 second
190 security
191 sensor
192 sensors
193 session
194 set
195 seven
196 seventeen
197 seventy
198 shed
199 shop
200 side
201 silent
202 siren
203 six
204 sixteen
205 sixty
206 skylight
207 sliding
208 smoke
209 sounder
210 south
211 space
212 spare
213 stairs
214 star
215 status
216 stay
217 stop
218 storage
219 study
220 sump
221 supervision
222 system
223 tamper
224 temperature
225 ten
226 terminated
227 thermostat
228 third
229 thirteen
230 thirty
231 three
232 to
233 tool
234 transmitted
235 transmitter
236 trouble
237 turn
238 twelve
239 twenty
240 two
241 unlock
242 upper
243 upstairs
244 user
245 utility
246 valve
247 voice
248 wall
249 water
250 west
251 window
252 wireless
253 yard
254 zero
255 zone

Q2. Wired Zones

There are two “ports” at attach wired sensors to the GoControl. In general, they are programmed the same as wireless zones, except that their “normal state” must be specified.

Normal State

0 Not Used
1 Normally Closed
3 Normally Open
4 Mixed with no EOL (End of Line)

Q3. Keyfobs

Emergency Key

0 Disables
1 Auxiliary
2 Audible
3 Silent Panic
4 Fire

Q4. Keypads